scxi-1357. National Instruments SCXI-1129 with electromechanical relays. scxi-1357

 
 National Instruments SCXI-1129 with electromechanical relaysscxi-1357  Work with our experts to sustain your critical applications

SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. View All (1) 0 Kudos Message 1 of 2 (1,492 Views) Reply. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01 高電圧scxiバックプレーン. Associated Part Numbers: 184366-01, 184366C-01, 184366D-01, 184366E-01, 776572-27. Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. Important Notice: Other. Work with our experts to sustain your critical applications. In Stock Ships Today: SCXI-1361: The SCXI-1361 is a National Instruments Rear Filler Panel with a Features Multiple SCXI Cables / Adapters . The NI 1359 and SCXI-1362 communication adapters provide the interface to your chassis through a• Combination chassis for SCXI and PXI/Compact PCI modules • House all SCXI modules Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. 1553. arincUsing the SCXI-1127 Switch Module National Instruments pg. Reinstall the strain-relief bar and tighten the strain-relief screws. BAN4 to LV6 cable Use this cable to connect theTB-2605 0. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. are not included with this equipment unless listed in the above stock item description. Answer: SCXI-1357 National Instruments This is a problem with the NI-DAQmx8. scxiスイッチはsh9md-auxケーブルとの接続にバックプレーンアダプタが必要です。バックプレーンはsh9md-auxから、バックプレーンの最も右側にあるスイッチの背面へ信号を経路設定します。 Quick Start Guide Installation Guide Guide Archived NI 1357 1358 1359 SCXI Controller Adapter Kit Installation Guide National Instruments 374133 324133 Technical Communications 374133c ni support compware manuals ||| INSTALLATION GUIDE NI 1357/1358/1359 SCXITM Controller/Adapter Kit Introduction This document des. The 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. Menu. 1553. Fieldpoint / CompactFieldpointCan i interchange a scxi 1357 8 slots communication adapter to same scxi -1001 , part no. Triggering for Switches (NI 4060 only)terminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital to analog conversion module (SCXI 1124). The AUX connector is meant to be used when a DMM is controlling a switch in an SCXI Chassis, like out SCXI-1130. SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. Refer to page 498 for more information on switch cabling. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. Each cable assembly includes a cable and one or more SCXI cable adapters. Downloadable Technical Manuals and Datasheets. Add to Cart. Switches. The 2,600 sq. following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. Read More Read Less. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. ¥Ifyou are using a PXI-1011 use an HV8-BAN4 cable. SCXI ™ SCXI-1127/1128 User Manual SCXI-1127/1128 User Manual December 2000 Edition Part Number 322149B-01 Worldwide Technical Support and Product Information ni. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. The NI PXI-4021 requires no extra programming other than the NI-SWITCH controller it receives with the National Instruments switches. Log on to ni. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Phone: (217) 352-9330. 009" 8. The output signal can easily be routed to an NI 4070 DMM to be measured. You can also route these signals to the NI 4060 or PXI-4070 FlexDMM for measurements. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. 1553. The NI SCXI-1343 is another option which is a general-purpose SCXI adapter with screw terminals. NI USB-1357/1358/1359 controller/adapter kits. SCXI-1127 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. Choose one of the following options to configure your device in MAX: • For devices cabled to an NI SCXI-1357/1358/1359 kit, proceed to . 8 in. This enables the SCXI system to be located closer to the sensors and transducers. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. SCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. These modules support the analog bus through a special adapter, the high-voltage analog bus (HVAB) backplane adapter in the SCXI-1357/1358 kit, at the rear of the module. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. lang:i-klingon score:10 filesize: 525. PXI-2503, SCXI-1127, SCXI-1128, or SCXI-1129, you can measure thousands of channels, consisting of voltages, thermocouples, RTDs,. Fieldpoint / CompactFieldpointView and Download National Instruments NI-488. This product is available in the market with multiple part numbers like 776575-57, 776575-571, 776575-572, and 185008B-01. following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Fax: (240) 376-1381. Each cable assembly includes a cable and one or more SCXI cable adapters. Site Search Results. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. 1553. Each cable assembly includes a cable and one or more SCXI cable adapters. This enables the SCXI system to be located closer to the sensors and transducers. Bruel & Kjaer JJ 2614 Input Adapter. National Instruments offers switches with scanning capabilities. National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThis unit is sealed in the manufacturer's bag. multiplexer/matrix modules. Homepage;The National Instruments SCXI-1346 is perfect for multichassis systems. This document contains information about the NI-DAQmx driver software, which you canarinc & 1553 . The National Instruments 1357,1358,1359 and SCXI-1362 communication adapters and high-voltage backplane assemblies provide several options for communication with and expansion ofthe functionality ofyour SCXI switch chassis. Choosing a Switch. previous page start next page. SCXI-1349 National Instruments SCXI-1349 Adapter Board from National Instruments | Buy Today from Artisan. These modules support the analog bus through a special adapter, the high-voltage analog bus (HVAB) backplane adapter in the SCXI-1357/1358 kit, at the rear of the module. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. To add more chassis to your high- The SCXI-1357 backplane adapter includes the High-Voltage Analog Backplane, or HVAB, connections. Particle Sizers / CountersSite Search Results. Physically connect the Measurement Complete output trigger from the DMM to the trigger input of the switch. To add more chassis to your high-Notes If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. 1 Data Acquisi tion System Set-upFind the National Instruments SCXI-1001 at our website: Click HERE. com for information on these kits. NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. Readers should have a basic knowledge of single module scanning hardware setup and programming. The NI PXI-4021 requires no extra programming other than the NI-SWITCH controller it receives with the National Instruments switches. HV8 connectors on the adapters allow you to easily route these signals to a DMM, such as the NI 4060/4070, for. Control Unit I/O Systems Controller Computer Hardware Measuring Instruments. Part Number: 185003A-01 . Click the Chassis tab. Particle Sizers / CountersSite Search Results. Alternatively, a switch controller installed in the rightmost PXI slot of anThe SCXI-1127,SCXI-1128 and SCXI-1129 have the capability to route analog signals to their rear connector. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. Some SCXI switches can route analog signals to their rear connector, and you can use the SCXI-1357 to share these signals among several modules in compatible chassis. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. 1553. arincSite Search Results. Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For. National Instruments SCXI-1129 with electromechanical relays. 1-slot adapters are sold separately. Mastering Windows 10/11 Deployment, 4 days New Dates Coming Soon… PowerShell for ConfigMgr and Intune, 3 days New Dates Coming Soon! Mastering. This unit ships in the opened National Instruments box. To add moreNational Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. National Instruments SH9MD-AUX HVAB Cable (1 Meter)Similar to the SH9MD-9MD. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. arincarinc & 1553 . This home was built in 1983 and last sold on. 1-slot adapters are sold separately. The cable assembly connects to the front-end signal conditioning SXCI. This enables the SCXI system to be located closer to the sensors and transducers. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the KitTengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. The NI USB-1357 is used with the NI driver tools NI. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. Re: Switch controller for SCXI 1128. ; Page 2 Thailand 662 992 7519, United Kingdom 44 0 1635 523545 For further support information, refer to the Technical Support and Professional Services. SCXI-1357, SCXI-1358, and SCXI-1359. † For devices cabled to an NI USB-1357/1358/1359 kit, where the NI USB-1359 is auto-detected and the chassis is auto-created in MAX as shown in Figure 10, complete the following steps. If your switch module cannot connect to the SCXI-1357 then you can use the SCXI-1362 Adapter Kit to connect to your DMM. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. Log on to ni. Part Number:NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Part Numbers: 185258-01, 185258B-01† For devices cabled to an NI SCXI-1357/1358/1359 kit, proceed to step 3. National Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 184793E-02To connect your NI 4060 to SCXI scanners and matrices, special cable kits are available (SCXI-1357 and SCXI-1358). Therefore, you can locate your SCXI system closer to your sensors and transducers. arincarinc & 1553 . arincarinc & 1553 . Expand the NI-DAQmx Devices tab. arincEmbedded & Industrial . The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. com for information on these kits. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HCAB create an SCXI-1357. Expand the NI-DAQmx Devices tab. The NI SCXI-1357 is manufactured with part numbers 776575-57, 776575-571 , 776575-572, and 185008B-01. 1553. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. This does not include any other equipment or cabling. This enables the SCXI system to be located closer to the sensors and transducers. Ensure the cable between SCXI chassis and DAQ devices is propperly connected or try another else cable assembly. Price: US $249. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Each cable assembly includes a cable and one or more SCXI cable adapters. This cable is included in theNI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Alternatively, a switch controller installed in the rightmost PXI slot of anThese Controllers are attuned with high-voltage backplane adapters like the SCXI-1357/1358. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the Kitof the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. 1 shows a pi cture of the actual system. arincarinc & 1553 . a switch controller to an SCXI switch module; the USB kit connects a. Single module information can be found in the NI. Figure 1. flathead screwdriver Long-nose pliers Wire cutter Wire insulation stripper Safety Information Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. 229 ASTM D374 Hardness (Shore A) 85 85 , (°C/W) 0. Fieldpoint / CompactFieldpointSCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. Embedded & Industrial . The 9 Pin DIN connectors for the SH9MD-AUX cable are circled in the Figure 5. It consists of a data acquisition board (PCI-MIO-16E- 4), terminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital-to-analog conversion module. computer to an SCXI switch module. for Solaris. Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. You can add insulation or padding if necessary. SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. BAN4 to LV6 cable Use this cable to connect theTB-2605 0. MXI / MXI-2 / MXI-3 / MXI-4. Site Search Results. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01National Instruments 181625-01 Rear Filler Panel for SCXI-1361. 1 Data Acquisi tion System Set-upSCXI-1327 Installation Guide 6 ni. C. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. · Combination chassis for SCXI and PXI/Compact PCI modules · House all SCX I modules Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. The cable assembly connects to the front-end signal conditioning SXCI. Part Number: 182675-01. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. Alternatively, a switch controller installed in the. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HVAB create an SCXI-1357. arincThe NI SCXI-1360 is a front filler panel, which can be used for covering the slot’s front side. Menu. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. Single module information can be found in the NI. 1553. tor backshell kit to ensure that the terminals are not accessible. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Note When connecting your signals to the SCXI-1327, follow the labeling on the SCXI-1327 for the appropriate module, as indicated in Figure 2. SCXI-1317 Circuit Parts Location Diagram 6. The SCXI-1357 consists of (2) 1-slot HVAB Adapters and (1) SCXI-1359 2-slot HVAB Adapter. arincarinc & 1553 . The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Work with our. Trusted Supplier for Industrial & Military. In Stock Ships Today: SCXI-1362:multiplexer/matrix modules. 1553. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. The output signal can easily be routed to an NI 4070 DMM to be measured. The SCXI-1362 works much like the SCXI. Leave jumper W1 on the SCXI-1100 in the factory-default (parking)Get a quote for a Used SCXI 1357 Miscellaneous Adapters from Apex Waves, LLC at used-line. Around 80% of the collection are research articles published in journals, 6% are papers from conference proceedings, 5% are book chapters, the rest are other types of documents. This model implements an advanced switching system, which is based on SCXI technology and does not need any other software. Alternatively, a switch controller installed in the rightmost PXI slot of anarinc & 1553 . The basic backplane is offered under the part number 776575-57, while the additional kit part numbers include aQuick Start Guide Installation Guide Guide Archived NI 1357 1358 1359 SCXI Controller Adapter Kit Installation Guide National Instruments 374133 324133 Technical Communications 374133c ni support compware manuals ||| INSTALLATION GUIDE NI 1357/1358/1359 SCXITM Controller/Adapter Kit Introduction This document describes. Readers should have a basic knowledge of single module scanning hardware setup and programming. The SCXI-1362 works much like the SCXI. 18455M-31. The USB-1357 is a high-voltage SCXI Plug-and-Play Backplane for USB. SCXI-1357 (4-Slot) (See Figure 6) We have New & Used SCXI-1357 Adapter Board by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. Work with our experts to sustain your critical applications. Readers should have a basic knowledge of single module scanning hardware setup and programming. Run the signal wires through the strain-relief opening. Alternatively, a switch controller installed in the rightmost PXI slot of an. Page 2 SCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01. Figure 1. National Instruments SCXI-1357 4-Slot High Voltage Backplane Adaptor. multiplexer/matrix modules. Fig. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Figure 1. MXI / MXI-2 / MXI-3 / MXI-4. The SCXI-1357 module can be used with and without cable to THE leave the DMM, control the SCXI chassis, and send the trigger to the SCXI. single-family home is a 3 bed, 1. If you want to share these analog signals among several modules, use an HVAB adapter such as the NI SCXI-1357/1358/1359. Right-click the chassis and choose. 4-Slot, High-Voltage SCXI Connector. 185436A-01 National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter from National Instruments | Buy Today from Artisan. Refer to page 507 for more information on switch cabling. arinc & 1553 . 178, 0. Refer to page 498 for more information on switch cabling. The NI USB-1357 is designed and manufactured by National Instruments. True-rms value of a signal. SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. previous page start next page. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USB. National Instruments offers switches with scanning capabilities. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USBThis does not include any other equipment or cabling. For the rear side, you should go with the NI SCXI-1361. 1553. arincNI 4021 switch controllers require an NI SCXI-1359/1358/1357 adapter kit to connect to an NI SCXI switch module. comDrives / Motion / Motor Control / Positioning. The cable HV8-BAN4 is used to connect SCXI backplanes to an NI DMM. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. For a completely plug-and-play solution that does not. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. The National Instruments 1357,1358,1359 and SCXI-1362 communication adapters and high-voltage backplane assemblies provide several options for communication with and expansion ofthe functionality ofyour SCXI switch chassis. The NI 1359 and SCXI-1362 communication adapters provide the interface to your chassis through aSCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. The high voltage backplane has the following specifications:Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high-voltage backplane. This product is available in the market with multiple part numbers like 776575-57, 776575-571, 776575-572, and 185008B-01. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. 1553. Single module information can be found in the NI. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. 1553. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. National Instruments manufactured this High Voltage Backplane. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. • For devices cabled to an NI USB-357/1358/1359 kit. Recorders / DataloggersSCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Fast Quotes & Shipping. Each cable assembly includes a cable and one or more SCXI cable adapters. 2 185444-02 SH9MD-AUX Use this cable to send digital control 1 185258-01 cable (Figure 10) signals from an NI 4021 switch controller 2 185258-02 or any NI DMM to SCXI switching systems. Single module information can be found in the NI. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Part Number: 181765-01 View Photo of broken connector. 79 N⋅ m (5 to 7 lb - in. 8 x 7. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. This home is currently off market - it last sold on August 30, 2019 for $647,500. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. The rear filler panel is developed to cover slots that remain unoccupied by multi-chassis adapters, cable assemblies, the SCXI-1357/SCXI-1358 backplane units, or cable extenders. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to 10 m. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. Other Industrial. . com ¥ ni. This enables the SCXI system to be located closer to the sensors and transducers. Tighten the terminal screws to a torque of 0. Alternatively, a switch controller installed in the. The probe sets meet IEC 1010 safety requirements and permit direct probing of circuits and cables. arincNI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to. arinc & 1553 . 1 shows a pi cture of the actual system. Single module information can be found in the NI. vi", found in the NI Example Finder in the folder Hardware Input and Output » Modular Instruments » NI-SWITCH (Switches). National Instruments offers switches with scanning capabilities. arincarinc & 1553 . Fig. Also for: Sb-gpib/tnt. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. Pin 9 on HVAB adapter NI SCXI-1357/1358/1359 connected to the module in Slot 12 Refer to the niSwitch Configure Scan Trigger VI or the niSwitch_ConfigureScanTrigger function for descriptions and values of the trigger inputs and scan advanced outputs. The SCXI-1357 consists ofa 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backpla ne components. The three. In Stock. The rear filler panel is developed to cover slots that remain unoccupied by multi-chassis adapters, cable assemblies, the SCXI-1357/SCXI-1358 backplane units, or cable extenders. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. arinc & 1553 . NI 9269 Getting Started Guide National. IBS Electronics distributes genuine National Instruments 776571-01 national instruments 776571-01 scxi-1001 120v (12-slot chassis). Each cable assembly includes a cable and one or more SCXI cable adapters. Ensure the modules are setup properly in the Modules tab to match the physical configuration of the chassis. To add moreFrom troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Part Number: 776575-581, 776575-582. The NI USB-1357 is used with the NI driver tools. 1553. Alternatively, a switch controller installed in the rightmost PXI slot of anThe PCI-4021 / PXI-4021 control switch devices such as SCXI-1102/B/C, SCXI-1124, SCXI-1127/1128, SCXI-116X family, and SCXI 1190/1191. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. ). Pin 9 on HVAB adapter NI SCXI-1357/1358/1359 connected to the module in Slot 12: Refer to the niSwitch Configure Scan Trigger VI or the niSwitch_ConfigureScanTrigger function for descriptions and values of the trigger inputs and scan advanced outputs. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. If your switch module cannot connect to the SCXI-1357 then you can use the SCXI-1362 Adapter Kit to connect to your DMM. Keep away from live circuits. The cable assembly connects to the front-end signal conditioning SXCI. ANE ASSEMBLY KIT 1 M CABLE SCXI-1357-01 4-SLOT HIGHVOLTAGE BACKPLANE CABLE ASSY,SCXI-1127,1M NI USB-1357 HIGH VOLTAGE BACKPLANE ASSEMBLY KIT 1 M CABLE SCXI-1357-02 4-SLOT HIGHVOLTAGE BACKPLANE. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This enables the SCXI system to be located closer to the sensors and transducers. 1553. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI-SCXI-1357 Controller module SCXI-1357 Controller module Module Clips Drive controller servo motor Contact: Mr. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. 1. To add moreQuick Start Guide Documentation Guide NI 9269 Getting Started Guide National Instruments apexwaves manuals ||| GETTING STARTED GUIDE NI 9269 100 kS/s/ch Simultaneous, 10 V, Isolated, 4-Channel C Series Voltage O. This does not include any cables. Tengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. Shakers / Stirrers / MixersThe NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. To add moreSCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. Experienced Expert Engineers that specialize in your applicationThe three available backplane kits are: SCXI-1357, SCXI-1358, and or SCXI-1359. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. Contact us. Fieldpoint / CompactFieldpointProducts from Manufacturer: Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. arincSCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. The SCXI-1357, crafted by National Instruments, is a High Voltage Backplane Adapter. arincNI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. tor backshell kit to ensure that the terminals are not accessible. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. of the National Instruments SCXI-1357/1358/1359 and the. The National Instruments SCXI-1346 is perfect for multichassis systems. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the Kit NI offers SCXI and USB versions of the 1357, 1358, and 1359 backplane adapter kits that can connect from two to eight SCXI switches. a. Alternatively, a switch controller installed in the. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. The SCXI 1325 is a screw terminal block that has 26 terminal for signal connections to the SCXI 1124 module. Alternatively, a switch controller installed in the rightmost PXI slot of anPage 2 SCXI Controller/Adapter Kit ™ This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. Add to cart. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. Condition: Used. Figure 1. Pin 9 on HVAB adapter NI SCXI-1357/1358/1359 connected to the module in Slot 12: Refer to the niSwitch Configure Scan Trigger VI or the niSwitch_ConfigureScanTrigger function for descriptions and values of the trigger inputs and scan advanced outputs. Particle Sizers / Countersabstract: pci-4060 pxi-4060 scxi-1357 4060 pxi-2501 pxi-2503 scxi-1127 scxi-1128 scxi-1129 Text: 4060 hardware, P -1 probe set, NI-DMM, DMM Soft Front Panel, and calibration certificate. multiplexer/matrix modules. NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. The USB-1357 is manufactured with the part number 776576-571. This Switch Controller is less expensive than other models and provides suitable control elucidation for switching modules. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. Particle Sizers / CountersSite Search Results. ¥Ifyou are using a PXI-1010 or an SCXI chassis use an SCXI-1357 or SCXI-1359 kit. The SCXI-1127 weighs 1 lb, and has the dimensions: 1. The NI SCXI-1129 has Free Ground Shipping and a 1-3 Year Warranty. This model can easily control many switching modules, which includes the following: the SCXI-1102/B/C, SCXI-1124, the SCXI-116X family, the SCXI 1190/1191, and the SCXI. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. 4-Slot, High-Voltage SCXI Connector—The SCXI-1357 is a high-voltage analog bus (HVAB) adapter. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers.